W99999999 · Wales
Heat pumps in Builth Wells (LD2): cost + BUS grant
TL;DR
- BUS grant of £7,500 toward an air-source heat pump applies in LD2 (Builth Wells) (Wales).
- Median EPC band across 1,495 local properties: D.
- 71% of homes sit at band D or below — typical retrofit candidates.
- Top property band in LD2 (Builth Wells): D (35%).
- MCS-certified installer required for a binding heat-loss quote.
What the EPC data shows for LD2 (Builth Wells)
We’ve aggregated the current Energy Performance Certificate band for 1,495 properties in LD2 (Builth Wells), drawn live from the GOV.UK EPC Register. The median home in our sample sits at band D, with 35% falling into band D and 24% in band C. Around 71% of homes are at band D or below — the cohort with the most realistic retrofit upside.
| Band | Properties | Share | Retrofit context |
|---|---|---|---|
| Band A | 9 | 0.6% | Already exceptional; heat pump replaces fossil heat directly |
| Band B | 68 | 4.5% | Strong fabric; heat-pump-ready after minor checks |
| Band C | 353 | 23.6% | Typical retrofit candidate; small upgrades likely |
| Band D | 516 | 34.5% | Insulation prerequisites likely; well-suited post-upgrade |
| Band E | 350 | 23.4% | Insulation recommendations typically required for BUS |
| Band F | 145 | 9.7% | Significant fabric improvements before heat pump fit |
| Band G | 54 | 3.6% | Fabric-first retrofit before any heat-pump consideration |
The typical LD2 (Builth Wells) home
What the EPC data shows beyond the headline rating — useful context for sizing a heat-pump install.
- Floor area: median 99 m² (25th–75th percentile: 72–143 m²). Heat-pump sizing scales roughly with floor area — expect a 5–8 kW unit at the median.
- Current heating cost: median £953/yr (£600– £1,507 typical range). The number an installer’s running-cost saving projection sits against.
- Mains gas connection: 46% of properties. Predominantly off-grid — heat-pump running-cost case is unambiguous vs oil and LPG.
- Property type mix: Detached 48%, End-Terrace 10%, Mid-Terrace 14%, Semi-Detached 26%.
- Dominant age band: England and Wales: before 1900 (29% of homes). Sets the fabric-first work expected before commissioning.
Does the Boiler Upgrade Scheme apply in LD2 (Builth Wells)?
Yes. LD2 (Builth Wells) is in Wales, where the Boiler Upgrade Scheme (BUS) pays £7,500 toward an air-source heat pump install. The grant is administered by Ofgem and deducted by the installer at the point of invoice — you never see the cash. To qualify, the property must be owner-occupied or privately rented, have a valid EPC issued in the last 10 years, and have no outstanding loft-or-cavity insulation recommendation on the EPC (unless an exemption is documented). In our sample of LD2 (Builth Wells) EPCs the median rating is band D, which means most homes need to clear at least one insulation recommendation before the installer can claim the grant.
Typical install cost in LD2 (Builth Wells)
Pre-grant install costs in LD2 (Builth Wells) typically run £8,000 to £14,000 for a 5–10 kW air-source unit, in line with UK averages — labour rates in W99999999 sit close to the national mean. After the £7,500 BUS deduction most LD2 (Builth Wells)homeowners pay £1,500 to £6,500 out of pocket. The figure within that range that applies to your property depends on three things: heat-loss sizing (set by floor area, fabric and air-tightness), radiator upgrades (most pre-2000s homes need at least one or two changed), and hot-water cylinder provision. An MCS-certified engineer issues the binding quote after a heat-loss calculation per BS EN 12831.
What this means for your home
Whether a heat pump is a good fit for your specific home in LD2 (Builth Wells)depends on three factors the EPC alone can’t answer: roof + outdoor space for the external unit, radiator sizing throughout the heating circuit, and your current heating fuel + tariff. Propertoasty’s free pre-survey check combines your address, an EPC pull, the Google Solar API’s roof data, and a floorplan vision analysis to produce an installer-ready report — typically takes about five minutes.
Run a free pre-survey check on your home — installer-ready report, BUS-eligibility verdict, sizing range, and a list of MCS-certified installers covering LD2 (Builth Wells).
Typical monthly heating cost in LD2 (Builth Wells)
Based on the median LD2 (Builth Wells) home in our EPC sample — a detached house around 99 m² — here’s what the two options look like on a like-for-like monthly total. Boiler numbers assume a £4,150 installed cost on 9.9% APR / 5-year finance plus a typical £20/mo service plan. Heat-pump numbers apply the £7,500 Boiler Upgrade Scheme grant and 0% APR / 10-year finance on the net cost of £6,500.
| Line | New gas boiler | Air-source heat pump |
|---|---|---|
| Finance | £88/mo | £54/mo |
| Energy | £117/mo | £134/mo |
| Service / cover | £20/mo | Not required |
| Total per month | £225/mo | £188/mo |
At today’s standard tariffs, that’s about £37/mo cheaper with the heat pump — roughly £444 a year. The gap grows on a dedicated heat-pump tariff (e.g. Octopus Cosy at 15p/kWh) and as gas prices rise relative to electricity across the 10-year finance term.
MCS-certified heat pump installers covering LD2 (Builth Wells) postcode area
We’ve matched these installers from the official MCS directory based on their service-area coverage of LD2 (Builth Wells) postcode area. Ratings come from Google verified reviews. To get an installer-ready suitability report and connect with one of them, click through to the free 5-minute check.
HES Plumbing & Electrical Ltd
47.2 km away · HR4 9HN
Covers: Air-source heat pump
- MCS #NIC-601578
- BUS registered
16 Google reviews
Verified Aug 2026
Free 5-minute property check first
Hereford Heating Ltd
47.2 km away · HR2 7RB
Covers: Air-source heat pump
- MCS #NIC-200057
- BUS registered
252 Google reviews
Verified Aug 2026
Free 5-minute property check first
Neon Heating & Boiler Services Ltd
46.8 km away · HR4 9SP
Covers: Air-source heat pump
- MCS #OFT-12974
- BUS registered
46 Google reviews
Verified Aug 2026
Free 5-minute property check first
Efficient Energy Centre (Hereford) Ltd t/a Efficient Energy Centre
46.3 km away · HR4 0EH
Covers: Air-source heat pump · Solar PV
- MCS #NAP-14595
- BUS registered
15 Google reviews
Verified Aug 2026
Free 5-minute property check first
Simply Biomass Ltd T/a Simply Renewables
15.3 km away · LD4 4DW
Covers: Air-source heat pump
- MCS #APH-47500
- BUS registered
—
Free 5-minute property check first
Liam Walker Plumbing and Heating Service
20.8 km away · ld6 5lt
Covers: Air-source heat pump · Solar PV
- MCS #NIC-5894
- BUS registered
—
Free 5-minute property check first
MJS Energy
31.5 km away · LD8 2HG
Covers: Air-source heat pump
- MCS #APH-46496
- BUS registered
—
Free 5-minute property check first
JJP Services Ltd
34.6 km away · SY18 6JH
Covers: Air-source heat pump · Solar PV
- MCS #NIC-600048
- BUS registered
—
Free 5-minute property check first
Rating data sourced from Google Maps. Powered by Google.
How LD2 (Builth Wells) compares
Compared with the England + Wales average band-D share of roughly 45%, LD2 (Builth Wells)’s 35% sits below the national midpoint. Bands E and worse — typical pre-1930s homes without significant retrofit — make up 37% of the local sample, which compares to the E&W average of around 22%.
Related postcode areas near LD2 (Builth Wells)
Same postcode area, useful if your property sits on a district boundary or you want to compare the wider area:
- Heat pumps in LD1 (Llandrindod Wells)
- Heat pumps in LD3 (Brecon)
- Heat pumps in LD4 (Llangammarch Wells)
- Heat pumps in LD5 (Llanwrtyd Wells)
- Heat pumps in LD6 (Rhayader)
- Heat pumps in LD7 (Knighton)
- Heat pumps in LD8 (Presteigne)
Nearby areas we cover
Adjacent local-authority and postcode areas — useful for comparing across a wider region:
- Heat pumps in Newport — local authority
- Heat pumps in Swansea — local authority
- Heat pumps in Cardiff — local authority
- Heat pumps in Bristol, City of — local authority
- Heat pumps in Wolverhampton — local authority
- Heat pumps in Walsall — local authority
- Heat pumps in Birmingham — local authority
- Heat pumps in Bath and North East Somerset — local authority
- Heat pumps in Stoke-on-Trent — local authority
- Heat pumps in Coventry — local authority
Heat pump cost by property size
Typical heat pump sizes for a home in LD2 (Builth Wells), with UK average install costs from government figures. The right-hand column shows what you actually pay after the £7,500 grant is deducted.
| Home size | Yearly usage | System size | Full price | What you pay after grant |
|---|---|---|---|---|
| 1-bed / flat | ≈8,000 kWh heat / yr | 5 kW ASHP | £9,500 | £2,000 |
| 2-3 bed | ≈12,000 kWh heat / yr | 7 kW ASHP | £12,500 | £5,000 |
| 4-5 bed | ≈18,000 kWh heat / yr | 11 kW ASHP | £15,500 | £8,000 |
These are UK-wide averages — your actual quote will vary with your roof, insulation, and installer. A guide only; your installer’s final quote will differ.
Also in LD2 (Builth Wells)
Every service page below is generated from the same local EPC + MCS-installer data as this one — pick whichever matches what you’re researching:
- Solar panels in LD2 (Builth Wells): cost + payback — guide + local EPC data.
- MCS heat pump installers in LD2 (Builth Wells) — directory, distance-ranked.
- MCS solar panel installers in LD2 (Builth Wells) — directory, distance-ranked.
Sources
- GOV.UK — Boiler Upgrade Scheme — accessed May 2026
- Ofgem — Boiler Upgrade Scheme guidance — accessed May 2026
- MCS — Find an installer — accessed May 2026
- GOV.UK — Find an energy certificate (EPC Register) — accessed May 2026
- Ofgem — Boiler Upgrade Scheme (BUS) — accessed May 2026
EPC aggregate data contains public sector information licensed under the Open Government Licence v3.0 (© Crown copyright and database right).